Searching…

115 Stuyvesant Place

Staten Island · Parcel 5000070050
107
Residential units
1925
Year built
83,646 sq ft
Building area
133
Open violations
$3,168,900
Assessed value

What the numbers say

Generated from this property's own figures using the rules set out in our methodology. Every statement below refers to a number shown on this page.

Already larger than residential zoning would allow

The building occupies a floor-area ratio of 4.19, against a residential limit of 2.43 — it is over that limit by 1.76. A building in this position almost always predates the current rules and is legally non-conforming: it may generally remain, but it typically cannot be enlarged for residential use, and it may not be rebuildable as it stands. A higher limit of 4.80 does apply to community-facility use, which produces an apparent 12,176 sq ft of headroom — but that is not residential floor area and is not interchangeable with it. Reading that number as room for more apartments is the most expensive mistake available in this data.

Unresolved conditions on record

133 violations remain open across 107 residential units (about 1.2 per apartment), against an outstanding penalty balance of $0.00. A significant open count with little money attached usually means habitability items that were never certified as corrected, rather than a few expensive enforcement actions — an administrative problem more than a financial one, though it is still a problem.

Assessed value trend

Assessed value has risen 3.1% across the 5 assessment years on record (2023 to 2027), standing at $3,168,900. Because tax is levied on the assessed figure rather than on market value, a sustained move here tends to show up in the bill.

Development & zoning

Floor-area ratio

Built4.19
Residential limit2.43
Commercial limit3.40
Community-facility limit4.80

Development headroom (calculated) calculated

Highest permitted ratio4.80
Unused ratio0.61
Unused buildable area12,176 sq ft
Lot area19,960 sq ft

Value & taxes

Assessment

Assessed total$3,168,900
Assessed land$449,100
Assessed building$2,719,800
Market value on record$6,801,000
Assessed as % of market46.6%

Tax

Tax class2
Taxable assessed$3,026,880
Tax rate12.502%
Estimated annual levy$378,420.54

The levy is an estimate — taxable value × the published rate for the class. It does not account for exemptions or abatements the property may carry, and will not match an actual bill. It is not the property's total debt to the city: unpaid tax and water arrears are not shown anywhere on this page.

Assessed value by year

YearAssessed valueChange
2027$3,060,450—
2026$2,975,400+2.9%
2025$2,972,250+0.1%
2024$3,157,650-5.9%
2023$2,968,650+6.4%

Building & occupancy

Structure

Year built1925
Floors6
Building area83,646 sq ft
Residential area81,546 sq ft
Commercial area2,100 sq ft

Occupancy

Total units108
Residential units107
Rent-stabilized108
Storefronts1
Residential Avg unit size762 sq ft (calculated)
Commercial Avg unit size2,100 sq ft (calculated)
Building classD7

Neighborhood, risk & energy

Neighborhood & transit

Nearest subwaySt George (SIR) — 0.18 mi
School district31
Police precinct120
Nearest firehouseEngine 155/Ladder 78 — 14 Brighton Avenue

Location risk

Flood zoneMinimal hazard (Zone X)
Hurricane evacuation zoneNot in an evacuation zone
City emergency repairs7 orders — $6,322 billed (through 2025)
Evictions on record2 (most recent 2026)

Energy & emissions

Energy use intensity91.9 kBtu/ft²
Greenhouse-gas emissions526 metric tons/yr

Record activity

Compliance calculated

Open violations133
Open per residential unit1.2 (calculated)
Enforcement penalties$0.00
Safety-violation penaltiesNot available
Total penalties owed$14,500.00 (calculated)
On tax-lien sale listNo

Activity

Complaints recorded547
Permits / alterations6
Recorded documents0
Legal proceedings0

Total penalties owed combines two separate debts — enforcement penalties (from summonses) and safety-violation penalties (unfiled inspections and reports on boilers, elevators, facades and energy use). The second kind accrues quietly and is routinely missed; it is a standing debt on the building, not a fine someone can walk away from. The safety figure could not be retrieved for this property, so no total is shown — we would rather show nothing than a total that silently omits it. Neither figure includes unpaid property tax or water and sewer arrears, which are frequently the largest number of all and appear nowhere on this page. For a true payoff figure, go to the city directly.

Ownership & last recorded sale

Owner of record

OwnerMcgregor Arms Realty Co
Parcel5000070050
Block7
Lot50

Last recorded transfer

Date—
Recorded price—
Price per unitNot meaningful
Price vs assessedNot meaningful

Owner of record comes from the public land-use record and may lag a recent sale. It is frequently a holding company rather than an individual. If you own or manage this property and believe something here is wrong, tell us — we read and respond to every message of that kind.

Open violations

Open violations only. A violation that was raised and later corrected is not counted — an older building accumulates hundreds of those, and the number says more about its age than its condition.

IssuedCategoryClassStatusAmount dueDescription
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD STORAGE AT PUBLIC HALL, 6th STORY
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY SECURE THE LOOSE 1ST BALUSTRADE FROM NORTH AT EAST AT PUBLIC HALL, 6th STORY
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY SECURE THE LOOSE 2ND BALUSTRADE FROM NORTH AT EAST AT PUBLIC HALL, 6th STORY
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY SECURE THE LOOSE 3RD BALUSTRADE FROM NORTH AT EAST AT PUBLIC HALL, 6th STORY
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY SECURE THE LOOSE 4TH BALUSTRADE FROM NORTH AT EAST AT PUBLIC HALL, 6th STORY
19 Nov 2026HousingCNOV SENT OUT—27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY
19 Nov 2026HousingCNOV SENT OUT—27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR SADDLE AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY SECURE THE LOOSE BALUSTRADE AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT 2nd PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY
19 Nov 2026HousingBNOV SENT OUT—28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AN
19 Nov 2026HousingCNOV SENT OUT—27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR AT 2nd PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY
19 Nov 2026HousingCNOV SENT OUT—27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AND LATCH AT DOOR AT 3rd PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY
19 Nov 2026HousingCNOV SENT OUT—27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE DOOR SADDLE AT 3rd PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY SECURE THE LOOSE BALUSTRADE AT 3rd PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY
19 Nov 2026HousingCNOV SENT OUT—27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR AT 4th PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY
19 Nov 2026HousingCNOV SENT OUT—27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR SADDLE AT 4th PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY
19 Nov 2026HousingCNOV SENT OUT—27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AND LATCH AT 7TH DOOR FROM SOUTH AT WEST AT CELLAR LEVEL AT PUBLIC HALL
19 Nov 2026HousingCNOV SENT OUT—27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT CELLAR LEVEL SECTION NORTH AT PUBLIC HALL
19 Nov 2026HousingCNOV SENT OUT—27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT CELLAR LEVEL SECTION NORTH AT PUBLIC HALL
19 Nov 2026HousingCNOV SENT OUT—27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING SLIDEBOLT CAPABLE OF PADLOCK AT 4TH DOOR FROM NORTH AT EAST AT CELLAR LEVEL SECTION SOUTH AT PUBLIC HALL
19 Nov 2026HousingCNOV SENT OUT—27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR AT SOUTH AT CELLAR LEVEL SECTION SOUTH AT PUBLIC HALL
19 Nov 2026HousingCNOV SENT OUT—27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WIRE AT DOOR AT SOUTH AT CELLAR LEVEL SECTION SOUTH AT PUBLIC HALL
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD STORAGE AT CELLAR LEVEL AT PUBLIC HALL
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 2ND CONCRETE RISER FROM BOTTOM UP AT STAIRS AT SOUTH AT CELLAR LEVEL SECTION SOUTH AT PUBLIC HALL
19 Nov 2026HousingCNOV SENT OUT—27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR AT CELLAR LEVEL AT LAUNDRY ROOM
19 Nov 2026HousingCNOV SENT OUT—27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING STRING AT DOOR AT CELLAR LEVEL AT LAUNDRY ROOM
19 Nov 2026HousingANOV SENT OUT—27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY CAPS AT 1ST ELECTRICAL OUTLET FROM WEST AT NORTH WALL AT CELLAR LEVEL AT LAUNDRY ROOM
19 Nov 2026HousingANOV SENT OUT—27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY CAPS AT 3RD ELECTRICAL OUTLET FROM WEST AT NORTH WALL AT CELLAR LEVEL AT LAUNDRY ROOM
19 Nov 2026HousingANOV SENT OUT—27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY CAPS AT 4TH ELECTRICAL OUTLET FROM WEST AT NORTH WALL AT CELLAR LEVEL AT LAUNDRY ROOM
19 Nov 2026HousingANOV SENT OUT—27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY CAPS AT 5TH ELECTRICAL OUTLET FROM WEST AT NORTH WALL AT CELLAR LEVEL AT LAUNDRY ROOM
19 Nov 2026HousingBNOV SENT OUT—27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE RUBBISH AT CELLAR LEVEL AT LAUNDRY ROOM
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 1ST STORY BALCONY AT 1ST FIRE ESCAPE FROM SOUTH AT EAST
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 3RD STORY BALCONY AT 1ST FIRE ESCAPE FROM SOUTH AT EAST
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 6TH STORY BALCONY AT FIRE ESCAPE AT NORTH
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 4TH STORY BALCONY AT FIRE ESCAPE AT NORTH
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 3RD STORY BALCONY AT FIRE ESCAPE AT NORTH
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 2ND STORY BALCONY AT FIRE ESCAPE AT NORTH
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 1ST STORY BALCONY AT FIRE ESCAPE AT NORTH
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 2ND STORY BALCONY AT 3RD FIRE ESCAPE FROM NORTH AT WEST AT BUILDING FRONT
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 5TH STORY BALCONY AT 1ST FIRE ESCAPE FROM NORTH AT WEST AT BUILDING FRONT
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 4TH STORY BALCONY AT 1ST FIRE ESCAPE FROM NORTH AT WEST AT BUILDING FRONT
19 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT 3RD STORY BALCONY AT 2ND FIRE ESCAPE FROM NORTH AT WEST AT BUILDING FRONT
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 10TH CONCRETE BULLNOSE FROM BOTTOM UP AT 1ST STAIRCASE FROM SOUTH AT WEST AT EAST YARD
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT 1ST COURT FROM SOUTH AT WEST AT EAST YARD
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT NORTH YARD
19 Nov 2026HousingBNOV SENT OUT—27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE RUBBISH AT NORTH YARD
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE REPLACE WITH NEW THE MISSING HAND RAIL AT 3RD STAIR CASE FROM SOUTH AT WEST AT EAST YARD
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 11TH AND 12TH CONCRETE RISERS FROM BOTTOM UP AT 2ND STAIRCASE FROM SOUTH AT WEST AT EAST YARD
19 Nov 2026HousingBNOV SENT OUT—27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 11TH CONCRETE TREAD FROM BOTTOM UP AT 2ND STAIRCASE FROM SOUTH AT WEST AT EAST YARD
4 Nov 2026HousingBNOV SENT OUT—27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWERS POTS AT 3RD STORY BALCONY AT 2ND STACK FROM NORTH AT BUILDING FRONT AT FIRE ESCAPE

Showing the 50 most recent of 133. The full set is available in the interactive report.

Complaints

A complaint is an allegation, not a finding — many are dismissed. A sustained pattern is nevertheless informative about how a building is run.

DateProblemTypeStatusClosed
13 Nov 2026ENTIRE BUILDINGHEAT/HOT WATERClosed17 Nov 2026
6 Nov 2026WATER SUPPLYPLUMBINGClosed9 Nov 2026
2 Nov 2026Banging/PoundingNoise - ResidentialClosed3 Nov 2026
1 Nov 2026Loud TalkingNoise - Street/SidewalkClosed2 Nov 2026
31 Oct 2026APARTMENT ONLYHEAT/HOT WATERClosed2 Nov 2026
20 Sep 2026Illegal Conversion Of Residential Building/SpaceBuilding/UseClosed21 Sep 2026
20 Sep 2026Allowed in Smoke Free AreaSmoking or VapingClosed24 Sep 2026
20 Sep 2026Allowed in Smoke Free AreaSmoking or VapingClosed24 Sep 2026
20 Sep 2026TrashDirty ConditionClosed21 Sep 2026
20 Sep 2026No Certificate Of Occupancy/Illegal/Contrary To COBuilding/UseClosed21 Sep 2026
20 Sep 2026No Certificate Of Occupancy/Illegal/Contrary To COBuilding/UseClosed23 Oct 2026
20 Sep 2026SRO - Illegal Work/No Permit/Change In Occupancy/UseBuilding/UseClosed23 Oct 2026
20 Sep 2026Illegal Hotel Rooms In Residential BuildingSpecial Projects Inspection Team (SPITClosed21 Sep 2026
20 Sep 2026GARBAGE/RECYCLING STORAGEUNSANITARY CONDITIONClosed1 Oct 2026
20 Sep 2026GARBAGE/RECYCLING STORAGEUNSANITARY CONDITIONClosed1 Oct 2026
19 Sep 2026Allowed in Smoke Free AreaSmoking or VapingClosed24 Sep 2026
19 Sep 2026Allowed in Smoke Free AreaSmoking or VapingClosed24 Sep 2026
18 Sep 2026Banging/PoundingNoise - ResidentialClosed18 Sep 2026
18 Sep 2026Banging/PoundingNoise - ResidentialClosed18 Sep 2026
18 Sep 2026Banging/PoundingNoise - ResidentialClosed18 Sep 2026
13 Sep 2026Banging/PoundingNoise - ResidentialClosed14 Sep 2026
13 Sep 2026Banging/PoundingNoise - ResidentialClosed13 Sep 2026
13 Sep 2026Banging/PoundingNoise - ResidentialClosed13 Sep 2026
12 Sep 2026Banging/PoundingNoise - ResidentialClosed13 Sep 2026
10 Sep 2026Storage Area Not ProvidedResidential Disposal ComplaintClosed11 Sep 2026
10 Sep 2026Banging/PoundingNoise - ResidentialClosed11 Sep 2026
9 Sep 2026Trash or Recycling Not SecureResidential Disposal ComplaintClosed11 Sep 2026
6 Sep 2026Allowed in Smoke Free AreaSmoking or VapingClosed24 Sep 2026
6 Sep 2026Allowed in Smoke Free AreaSmoking or VapingClosed24 Sep 2026
3 Sep 2026Allowed in Smoke Free AreaSmoking or VapingClosed24 Sep 2026
22 Aug 2026Banging/PoundingNoise - ResidentialClosed23 Aug 2026
22 Aug 2026Banging/PoundingNoise - ResidentialClosed22 Aug 2026
21 Aug 2026Banging/PoundingNoise - ResidentialClosed21 Aug 2026
18 Aug 2026Loud TelevisionNoise - ResidentialClosed18 Aug 2026
18 Aug 2026Loud TelevisionNoise - ResidentialClosed18 Aug 2026
18 Aug 2026Loud TelevisionNoise - ResidentialClosed18 Aug 2026
18 Aug 2026Banging/PoundingNoise - ResidentialClosed18 Aug 2026
18 Aug 2026Banging/PoundingNoise - ResidentialClosed18 Aug 2026
18 Aug 2026Banging/PoundingNoise - ResidentialClosed18 Aug 2026
17 Aug 2026Banging/PoundingNoise - ResidentialClosed18 Aug 2026
16 Aug 2026Banging/PoundingNoise - ResidentialClosed17 Aug 2026
16 Aug 2026Banging/PoundingNoise - ResidentialClosed17 Aug 2026
16 Aug 2026Banging/PoundingNoise - ResidentialClosed16 Aug 2026
11 Aug 2026Banging/PoundingNoise - ResidentialClosed11 Aug 2026
10 Aug 2026Allowed in Smoke Free AreaSmoking or VapingClosed24 Sep 2026
10 Aug 2026Allowed in Smoke Free AreaSmoking or VapingClosed24 Sep 2026
9 Aug 2026SIGNAGE MISSINGGENERALClosed28 Aug 2026
9 Aug 2026Pigeon WasteUnsanitary Pigeon ConditionClosed12 Aug 2026
5 Aug 2026Banging/PoundingNoise - ResidentialClosed5 Aug 2026
31 Jul 2026Banging/PoundingNoise - ResidentialClosed1 Aug 2026

Showing the 50 most recent of 150. The full set is available in the interactive report.

Permits & alterations

The absence of a permit does not prove no work was done — it may equally mean work was done without one.

IssuedTypeStatusWork
10 Apr 2012A3ISSUED—
28 Sep 2007A2ISSUED—
3 Jan 2005A3ISSUED—
8 Dec 2004A3ISSUED—
15 Aug 2000A2ISSUED—
22 Sep 1994A2ISSUED—

About this page

Compiled from New York City public records — data retrieved 1 day ago. Coverage on this parcel: 15 of 15 record groups populated. The derived figures — unused floor-area ratio, buildable area, the assessed-value trend and the per-unit ratios — are calculated by us and appear in no public dataset; the formulas are in the methodology.

This is a research tool, not advice. It is not a title search, a lien search, a survey or an inspection, and it does not replace any of them. If a figure here matters to a decision, verify it at the source. See Terms.