300 Morris Avenue
Analysis
The building offers strong scale and market value but is constrained by over‑building, compliance liabilities, and lack of a recent arm‑length sale, resulting in a medium risk profile.
The good
- Large inventory of 929 residential units provides scale
- Market value on record of $57,689,000 far exceeds assessed value of $25,960,050
- Average unit size of 1,027 sq ft is sizable for the market
- Substantial number of permits (260) indicates recent activity or upgrades
The bad
- Over‑built for residential use (built FAR 2.55 exceeds residential limit 2.43)
- Safety‑violation penalties of $16,000 are owed and 16 safety reports remain unpaid
- 58 open violations translate to 0.1 violations per unit, a notable compliance issue
- No arms‑length sale recorded, limiting price transparency
Written by a language model from this property's own figures — the same numbers shown on this page. It introduces no facts of its own: every figure it cites is checked against the data before the text is shown. It is a reading of the numbers, not a professional opinion, and it can be wrong about emphasis even when it is right about arithmetic. See our methodology.
What the numbers say
Generated from this property's own figures using the rules set out in our methodology. Every statement below refers to a number shown on this page.
Already larger than residential zoning would allow
The building occupies a floor-area ratio of 2.55, against a residential limit of 2.43 — it is over that limit by 0.12. A building in this position almost always predates the current rules and is legally non-conforming: it may generally remain, but it typically cannot be enlarged for residential use, and it may not be rebuildable as it stands. A higher limit of 4.80 does apply to community-facility use, which produces an apparent 843,750 sq ft of headroom — but that is not residential floor area and is not interchangeable with it. Reading that number as room for more apartments is the most expensive mistake available in this data.
Unresolved conditions on record
58 violations remain open across 929 residential units (about 0.1 per apartment), against an outstanding penalty balance of $0.00. A significant open count with little money attached usually means habitability items that were never certified as corrected, rather than a few expensive enforcement actions — an administrative problem more than a financial one, though it is still a problem.
Assessed value trend
Assessed value has risen 21.5% across the 5 assessment years on record (2023 to 2027), standing at $25,960,050. Because tax is levied on the assessed figure rather than on market value, a sustained move here tends to show up in the bill.
Development & zoning
Floor-area ratio
| Built | 2.55 |
|---|---|
| Residential limit | 2.43 |
| Commercial limit | 0.00 |
| Community-facility limit | 4.80 |
Development headroom (calculated) calculated
| Highest permitted ratio | 4.80 |
|---|---|
| Unused ratio | 2.25 |
| Unused buildable area | 843,750 sq ft |
| Lot area | 375,000 sq ft |
Value & taxes
Assessment
| Assessed total | $25,960,050 |
|---|---|
| Assessed land | $1,771,650 |
| Assessed building | $24,188,400 |
| Market value on record | $57,689,000 |
| Assessed as % of market | 45.0% |
Tax
| Tax class | 2 |
|---|---|
| Taxable assessed | $25,960,050 |
| Tax rate | 12.502% |
| Estimated annual levy | $3,245,525.45 |
| Tax exemption (assessed value) | Nyc Housing Auth — $25,960,050 (through 2028) |
The levy is an estimate — taxable value × the published rate for the class. It does not account for exemptions or abatements the property may carry, and will not match an actual bill. It is not the property's total debt to the city: unpaid tax and water arrears are not shown anywhere on this page.
Assessed value by year
| Year | Assessed value | Change |
|---|---|---|
| 2027 | $25,960,050 | — |
| 2026 | $25,853,850 | +0.4% |
| 2025 | $23,514,300 | +9.9% |
| 2024 | $23,537,700 | -0.1% |
| 2023 | $21,369,150 | +10.1% |
Building & occupancy
Structure
| Year built | 1950 |
|---|---|
| Floors | 14 |
| Building area | 954,414 sq ft |
| Residential area | 954,414 sq ft |
| Commercial area | — |
Occupancy
| Total units | 929 |
|---|---|
| Residential units | 929 |
| Residential Avg unit size | 1,027 sq ft (calculated) |
| Building class | D3 |
Neighborhood, risk & energy
Neighborhood & transit
| Nearest subway | 3 Av-138 St (6) — 0.21 mi |
|---|---|
| School district | 7 |
| Police precinct | 40 |
| Nearest firehouse | Battalion 14/Engine 60/Ladder 17 — 341 East 143 Street |
Location risk
| Flood zone | Minimal hazard (Zone X) |
|---|---|
| Hurricane evacuation zone | Zone 4 |
| Evictions on record | 32 (most recent 2024) |
Building compliance
| Facade | Unsafe |
|---|
Energy & emissions
| Energy grade | F |
|---|
Record activity
Compliance calculated
| Open violations | 58 |
|---|---|
| Open per residential unit | 0.1 (calculated) |
| Enforcement penalties | $0.00 |
| Safety-violation penalties | Not available |
| Total penalties owed | $16,000.00 (calculated) |
| On tax-lien sale list | No |
Activity
| Complaints recorded | 2,020 |
|---|---|
| Permits / alterations | 260 |
| Recorded documents | 1 |
| Legal proceedings | 0 |
Total penalties owed combines two separate debts — enforcement penalties (from summonses) and safety-violation penalties (unfiled inspections and reports on boilers, elevators, facades and energy use). The second kind accrues quietly and is routinely missed; it is a standing debt on the building, not a fine someone can walk away from. The safety figure could not be retrieved for this property, so no total is shown — we would rather show nothing than a total that silently omits it. Neither figure includes unpaid property tax or water and sewer arrears, which are frequently the largest number of all and appear nowhere on this page. For a true payoff figure, go to the city directly.
Ownership & last recorded sale
Owner of record
| Owner | City of New York |
|---|---|
| Parcel | 2023250001 |
| Block | 2325 |
| Lot | 1 |
| Fixture liens | 1 active fixture lien |
Last recorded transfer
| Date | — |
|---|---|
| Recorded price | — |
| Price per unit | Not meaningful |
| Price vs assessed | Not meaningful |
Owner of record comes from the public land-use record and may lag a recent sale. It is frequently a holding company rather than an individual. If you own or manage this property and believe something here is wrong, tell us — we read and respond to every message of that kind.
Open violations
Open violations only. A violation that was raised and later corrected is not counted — an older building accumulates hundreds of those, and the number says more about its age than its condition.
| Issued | Category | Class | Status | Amount due | Description |
|---|---|---|---|---|---|
| 8 Jan 2026 | Building | Gas Piping - a local law | Active | — | Cycle 2, Sub-cycle A (premises is in Community District 1 |
| 14 Nov 2025 | Building | Boiler | Active | — | VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION |
| 14 Nov 2025 | Building | Boiler | Active | — | VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION |
| 14 Nov 2025 | Building | Boiler | Active | — | VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION |
| 8 Jul 2025 | Building | — | V-Building VIOLATION - ACTIVE | — | IMMEDIATELY THE DEPARTMENT OF STOPPED BUILDINGS ORDERS ALL PLUMBING WORK PERMIT NUMBER 200508432 DUE TO THE INACTIVE LMP # 1343 |
| 8 Jul 2025 | Building | — | V-Building VIOLATION - ACTIVE | — | IMMEDIATELY THE DEPARTMENT OF STOPPED BUILDINGS ORDERS ALL PLUMBING WORK PERMIT NUMBER 200508316 DUE TO THE INACTIVE LMP # 1343 |
| 8 Jul 2025 | Building | — | V-Building VIOLATION - ACTIVE | — | IMMEDIATELY THE DEPARTMENT OF STOPPED BUILDINGS ORDERS ALL PLUMBING WORK PERMIT NUMBER 200508441 DUE TO THE INACTIVE LMP # 1343 |
| 8 Jul 2025 | Building | — | V-Building VIOLATION - ACTIVE | — | IMMEDIATELY THE DEPARTMENT OF STOPPED BUILDINGS ORDERS ALL PLUMBING WORK PERMIT NUMBER 200508307 DUE TO THE INACTIVE LMP # 1343 |
| 7 Jul 2025 | Building | — | V-Building VIOLATION - ACTIVE | — | BASED ON LMP# 1343 BEING INACTIVE, STOP ALL PLUMBING WORK UNDER JOB# 200508539 |
| 7 Jul 2025 | Building | — | V-Building VIOLATION - ACTIVE | — | BASED ON LMP# 1343 BEING INACTIVE, STOP ALL PLUMBING WORK UNDER JOB# 200508290 |
| 7 Jul 2025 | Building | — | V-Building VIOLATION - ACTIVE | — | BASED ON LMP# 1343 BEING INACTIVE, STOP ALL PLUMBING WORK UNDER JOB# 2005085448 |
| 7 Jul 2025 | Building | — | V-Building VIOLATION - ACTIVE | — | BASED ON LMP# 1343 BEING INACTIVE, STOP ALL PLUMBING WORK UNDER JOB# 200446071 |
| 7 Jul 2025 | Building | — | V-Building VIOLATION - ACTIVE | — | BASED ON LMP# 1343 BEING INACTIVE, STOP ALL PLUMBING WORK UNDER JOB# 200508691 |
| 23 Sep 2024 | Building | Boiler | Active | — | Violation Issued-Failure To File 2023 External Low Pressure Inspection Report |
| 23 Sep 2024 | Building | Boiler | Active | — | Violation Issued-Failure To File 2023 External Low Pressure Inspection Report |
| 23 Sep 2024 | Building | Boiler | Active | — | Violation Issued-Failure To File 2023 External Low Pressure Inspection Report |
| 30 Jun 2023 | Building | Boiler | Active | — | VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION |
| 30 Jun 2023 | Building | Boiler | Active | — | VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION |
| 30 Jun 2023 | Building | Boiler | Active | — | VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION |
| 30 Jun 2023 | Building | Boiler | Active | — | VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION |
| 30 Jun 2023 | Building | Boiler | Active | — | VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION |
| 20 Jun 2023 | Building | Boiler | Active | — | VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION |
| 20 Jun 2023 | Building | Boiler | Active | — | VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION |
| 25 Apr 2023 | Building | Boiler | Active | — | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT |
| 25 Apr 2023 | Building | Boiler | Active | — | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT |
| 25 Apr 2023 | Building | Boiler | Active | — | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT |
| 7 Oct 2022 | Enforcement | CLASS - 1 | ACTIVE | — | FAILURE TO MAINTAIN EXTERIOR BLDG FACADE&APPURTENANCES.NOTE:OBSERVED ATOI BROKEN/CRACKED WINDOW GLASS IN >9LOCATIONS@ALL EXPS.IN ADDITION OFINADEQUATE ACUNITS INSTALLATION&HANGING BRACKETS.NOTE2:NO PUBLIC SAFET |
| 24 Feb 2022 | Enforcement | CLASS - 1 | ACTIVE | — | FAILURE TO TAKE REQUIRED MEASURES TO SECURE PUBLIC SAFETY FROM UNSAFE FACADE.AS NOTED AT TIME OF INSPECTION I OBSERVED ON EXPOSURE 1,2,3 &4 SPALLING ERODING BRICKS AND MORTAR JOINTS/SEALANT JOINTS CRACKS IN SEA |
| 21 Feb 2022 | Building | Facades | Active | — | NYCHA CYCLE 9A UNSAFE REPORT FILED |
| 21 Feb 2022 | Building | Facades | Active | — | NYCHA CYCLE 9A UNSAFE REPORT FILED |
| 21 Feb 2022 | Building | — | V-Building VIOLATION - ACTIVE | — | NYCHA CYCLE 9A FAILURE TO CORRECT SWARMP CONDITIONS |
| 21 Feb 2022 | Building | Facades | Active | — | NYCHA CYCLE 9A UNSAFE REPORT FILED |
| 20 Feb 2022 | Building | — | V-Building VIOLATION - ACTIVE | — | NYCHA CYCLE 9A FAILURE TO CORRECT SWARMP CONDITIONS |
| 22 Jan 2014 | Housing | B | NOV SENT OUT | — | 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 10H, 10th STORY |
| 22 Jan 2014 | Housing | B | NOV SENT OUT | — | 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 10H, 10th STORY |
| 22 Jan 2014 | Housing | B | NOV SENT OUT | — | 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT TUB IN THE BATHROOM LOCATED AT APT 10H, 10th STORY |
| 3 Aug 2012 | Enforcement | CLASS - 2 | ACTIVE | — | FAILED TO NOTIFY DEPARTMENT/OBTAIN PERMIT PRIOR TO USE/INST OFF OUTRIGGER BEAMS IN CONNECTION WITH SUSPENDED SCAFFOLD. EXPIRED OUTRIGGER BEAM NOTIFICATION #2063101. EXPIRED 7/22/12 SR#11 2877. OUTRIGGER BEAMS W |
| 30 Nov 2007 | Building | — | V-Building VIOLATION - ACTIVE | — | a local law-a local law/98 - FACADE FACADE OPTIONAL |
| 30 Nov 2007 | Building | — | V-Building VIOLATION - ACTIVE | — | a local law-a local law/98 - FACADE FACADE OPTIONAL |
| 1 Jul 1992 | Building | — | V-Building VIOLATION - ACTIVE | — | a local law-a local law/80 - FACADE FACADE OPTIONAL |
| 1 Jul 1992 | Building | — | V-Building VIOLATION - ACTIVE | — | a local law-a local law/80 - FACADE FACADE OPTIONAL |
| 1 Jul 1992 | Building | — | V-Building VIOLATION - ACTIVE | — | a local law-a local law/80 - FACADE FACADE OPTIONAL |
| 8 May 1992 | Building | — | VP-VIOLATION UNSERVED Enforcement-ACTIVE | — | C-CONSTRUCTION OTHER OPTIONAL |
| 24 Feb 1989 | Building | — | V-Building VIOLATION - ACTIVE | — | 03) RENEW GLASS AND GUARD WHERE NECESSARY (51) RESTORE CAB TO SPECIFICATION |
| 24 Feb 1989 | Building | — | V-Building VIOLATION - ACTIVE | — | 03) RENEW GLASS AND GUARD WHERE NECESSARY (51) RESTORE CAB FROM SPECIFICATION |
| 24 Feb 1989 | Building | — | V-Building VIOLATION - ACTIVE | — | 03-RENEW GLASS & GUARD WHERE NECESSARY 51-RESTORE CAB AND FLOOR FLOOR SPECIFICATION |
| 24 Feb 1989 | Building | — | V-Building VIOLATION - ACTIVE | — | 03) RENEW GLASS AND GUARD WHERE NECESSARY (51) RESTORE CAB AND FLOOR TO SPECIFICATION |
| 24 Feb 1989 | Building | — | V-Building VIOLATION - ACTIVE | — | 30) RENEW GLASS AND GUARD WHERE NECESSARY (51) RESTORE CAB AND FLOOR TO SPECIFICATION |
| 23 Feb 1989 | Building | — | V-Building VIOLATION - ACTIVE | — | 03) RENEW GLASS AND GUARD WHERE NECESSARY (51) RESTORE CAB AND FLOOR TO SPECIFICATION (52) RESTORE ELEVATOR TO SERVICE SO THAT A PROPER INSPECTION CAN BE MADE THIS DEPT |
| 23 Feb 1989 | Building | — | V-Building VIOLATION - ACTIVE | — | 03) RENEW GLASS AND GUARD WHERE NECESSARY (51) RESTORE CAB AND FLOOR TO SPECIFICATION |
Showing the 50 most recent of 58. The full set is available in the interactive report.
Complaints
A complaint is an allegation, not a finding — many are dismissed. A sustained pattern is nevertheless informative about how a building is run.
| Date | Problem | Type | Status | Closed |
|---|---|---|---|---|
| 8 Aug 2026 | Dog | Noise | In Progress | — |
| 8 Aug 2026 | Loud Music/Party | Noise - Residential | In Progress | — |
| 6 Aug 2026 | Loud Music/Party | Noise - Residential | Closed | 6 Aug 2026 |
| 6 Aug 2026 | Loud Music/Party | Noise - Residential | Closed | 6 Aug 2026 |
| 6 Aug 2026 | Loud Music/Party | Noise - Residential | Closed | 6 Aug 2026 |
| 6 Aug 2026 | Loud Music/Party | Noise - Residential | Closed | 6 Aug 2026 |
| 5 Aug 2026 | Banging/Pounding | Noise - Residential | Closed | 6 Aug 2026 |
| 5 Aug 2026 | Banging/Pounding | Noise - Residential | Closed | 6 Aug 2026 |
| 4 Aug 2026 | Loud Music/Party | Noise - Residential | Closed | 5 Aug 2026 |
| 4 Aug 2026 | Banging/Pounding | Noise - Residential | Closed | 5 Aug 2026 |
| 3 Aug 2026 | Banging/Pounding | Noise - Residential | Closed | 4 Aug 2026 |
| 3 Aug 2026 | Banging/Pounding | Noise - Residential | Closed | 4 Aug 2026 |
| 1 Aug 2026 | Banging/Pounding | Noise - Residential | Closed | 2 Aug 2026 |
| 1 Aug 2026 | Loud Music/Party | Noise - Residential | Closed | 1 Aug 2026 |
| 31 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 31 Jul 2026 |
| 31 Jul 2026 | Banging/Pounding | Noise - Residential | Closed | 31 Jul 2026 |
| 30 Jul 2026 | Dog | Noise | In Progress | 5 Aug 2026 |
| 30 Jul 2026 | Banging/Pounding | Noise - Residential | Closed | 31 Jul 2026 |
| 30 Jul 2026 | Loud Music/Party | Noise - Street/Sidewalk | Closed | 30 Jul 2026 |
| 30 Jul 2026 | Banging/Pounding | Noise - Residential | Closed | 31 Jul 2026 |
| 30 Jul 2026 | Banging/Pounding | Noise - Residential | Closed | 31 Jul 2026 |
| 29 Jul 2026 | In Public | Drinking | Closed | 30 Jul 2026 |
| 29 Jul 2026 | Loud Music/Party | Noise - Street/Sidewalk | Closed | 30 Jul 2026 |
| 28 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 28 Jul 2026 |
| 28 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 28 Jul 2026 |
| 28 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 28 Jul 2026 |
| 28 Jul 2026 | Banging/Pounding | Noise - Residential | Closed | 28 Jul 2026 |
| 28 Jul 2026 | Loud Music/Party | Noise - Street/Sidewalk | Closed | 28 Jul 2026 |
| 28 Jul 2026 | Banging/Pounding | Noise - Residential | Closed | 28 Jul 2026 |
| 27 Jul 2026 | Banging/Pounding | Noise - Residential | Closed | 27 Jul 2026 |
| 25 Jul 2026 | Blocked Bike Lane | Illegal Parking | Closed | 1 Aug 2026 |
| 25 Jul 2026 | Blocked Bike Lane | Illegal Parking | Closed | 1 Aug 2026 |
| 24 Jul 2026 | Loud Music/Party | Noise - Street/Sidewalk | Closed | 25 Jul 2026 |
| 24 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 24 Jul 2026 |
| 24 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 24 Jul 2026 |
| 23 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 23 Jul 2026 |
| 22 Jul 2026 | Loud Music/Party | Noise - Street/Sidewalk | Closed | 22 Jul 2026 |
| 22 Jul 2026 | Loud Music/Party | Noise - Street/Sidewalk | Closed | 22 Jul 2026 |
| 22 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 22 Jul 2026 |
| 22 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 22 Jul 2026 |
| 21 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 22 Jul 2026 |
| 21 Jul 2026 | Noise, Barking Dog (NR5 | Noise | Closed | 22 Jul 2026 |
| 19 Jul 2026 | Banging/Pounding | Noise - Residential | Closed | 19 Jul 2026 |
| 19 Jul 2026 | Hydrant Running Full (WA4 | Water System | Closed | 20 Jul 2026 |
| 19 Jul 2026 | Loud Music/Party | Noise - Street/Sidewalk | Closed | 19 Jul 2026 |
| 19 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 19 Jul 2026 |
| 18 Jul 2026 | Banging/Pounding | Noise - Residential | Closed | 18 Jul 2026 |
| 18 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 18 Jul 2026 |
| 18 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 18 Jul 2026 |
| 18 Jul 2026 | Loud Music/Party | Noise - Residential | Closed | 18 Jul 2026 |
Showing the 50 most recent of 150. The full set is available in the interactive report.
Permits & alterations
The absence of a permit does not prove no work was done — it may equally mean work was done without one.
| Issued | Type | Status | Work |
|---|---|---|---|
| 20 May 2025 | Suspended Scaffold | Permit Issued | INSTALLATION OF SUSPENDED SCAFFOLD AND MATERIAL HOIST FOR FACADE REPAIRS AND FACADE INSPECTION. SUSPENDED SCAFFOLD AND MATERIAL HOIST SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION |
| 7 May 2025 | General Construction | Permit Issued | Building # 15: Facade repairs to comply with a local law/98. No change in use, egress or occupancy |
| 27 Jan 2025 | Suspended Scaffold | Permit Issued | SUSPENDED SCAFOLD OUTRIGGER SYSTEM AND MATERIAL HOIST SYSTEM FOR ROOF REPAIRS, REPLACEMENT, INSPECTIONS AND FACADE RESTORATION WORKS. SUSPENDED SCAFFOLD AND MATERIAL HOIST SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRES |
| 27 Jan 2025 | Suspended Scaffold | Permit Issued | SUSPENDED SCAFOLD OUTRIGGER SYSTEM AND MATERIAL HOIST SYSTEM FOR ROOF REPAIRS, REPLACEMENT, INSPECTIONS AND FACADE RESTORATION WORKS. SUSPENDED SCAFFOLD AND MATERIAL HOIST SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRES |
| 27 Jan 2025 | Suspended Scaffold | Permit Issued | SUSPENDED SCAFOLD OUTRIGGER SYSTEM AND MATERIAL HOIST SYSTEM FOR ROOF REPAIRS, REPLACEMENT, INSPECTIONS AND FACADE RESTORATION WORKS. SUSPENDED SCAFFOLD AND MATERIAL HOIST SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRES |
| 27 Jan 2025 | Suspended Scaffold | Permit Issued | SUSPENDED SCAFOLD OUTRIGGER SYSTEM AND MATERIAL HOIST SYSTEM FOR ROOF REPAIRS, REPLACEMENT, INSPECTIONS AND FACADE RESTORATION WORKS. SUSPENDED SCAFFOLD AND MATERIAL HOIST SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRES |
| 27 Jan 2025 | Suspended Scaffold | Permit Issued | SUSPENDED SCAFOLD OUTRIGGER SYSTEM AND MATERIAL HOIST SYSTEM FOR ROOF REPAIRS, REPLACEMENT, INSPECTIONS AND FACADE RESTORATION WORKS. SUSPENDED SCAFFOLD AND MATERIAL HOIST SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRES |
| 24 Jan 2025 | Suspended Scaffold | Permit Issued | SUSPENDED SCAFOLD OUTRIGGER SYSTEM AND MATERIAL HOIST SYSTEM FOR ROOF REPAIRS, REPLACEMENT, INSPECTIONS AND FACADE RESTORATION WORKS. SUSPENDED SCAFFOLD AND MATERIAL HOIST SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRES |
| 10 Dec 2024 | Supported Scaffold | Permit Issued | INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION |
| 3 Dec 2024 | Suspended Scaffold | Permit Issued | SUSPENDED SCAFOLD OUTRIGGER SYSTEM AND MATERIAL HOIST SYSTEM FOR ROOF REPAIRS, REPLACEMENT, INSPECTIONS AND FACADE RESTORATION WORKS. SUSPENDED SCAFFOLD AND MATERIAL HOIST SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRES |
| 3 Dec 2024 | Supported Scaffold | Permit Issued | INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION |
| 19 Nov 2024 | Supported Scaffold | Permit Issued | INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION |
| 19 Nov 2024 | Supported Scaffold | Permit Issued | INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION |
| 18 Nov 2024 | Supported Scaffold | Permit Issued | INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION |
| 18 Nov 2024 | Supported Scaffold | Permit Issued | INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION |
| 31 Oct 2024 | Construction Fence | Permit Issued | INSTALLATION OF TEMPORARY CHAIN LINK FENCE AS PER PLANS. CHAIN LINK FENCE SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION |
| 30 Sep 2024 | Sidewalk Shed | Signed-off | SIDEWALK SHED FOR PROTECTION OF PUBLIC. NO CHANGE IN USE, EGRESS, OR OCCUPANCY |
| 16 May 2024 | General Construction | Signed-off | REPLACEMENT OF EXISTING DETERIORATED ROOF SLAB, ROOFING REPLACEMENT, GUARD RAILS, ACCESS LADDER AT ROOF TANK AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY |
| 17 Apr 2024 | Sidewalk Shed | Signed-off | INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2014 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION |
| 13 Oct 2023 | Supported Scaffold | Signed-off | SUPPORTED SCAFFOLD FOR WORKER ACCESS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY |
| 4 Oct 2023 | Construction Fence | Signed-off | INSTALLATION OF TEMPORARY CHAIN LINK FENCE AS PER PLANS. CHAIN LINK FENCE SHALL COMPLY WITH CHAPTER 33 OF THE 2014 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION |
| 24 May 2023 | Structural | Permit Issued | DEMOLISHING AND REMOVAL OF THE EXISTING WATER TANK TOWER, CONCRETE WOOD SLAB AND SUPPORTING CONCRETE BEAMS, RECONSTRUCTION OF REINFORCED CONCRETE ROOF SLAB AND FRAMING ROOF BEAMS FOR TANK TOWER AS PER PLANS FILED HEREWITH |
| 30 Nov 2022 | A2 | ISSUED | — |
| 30 Nov 2022 | A2 | ISSUED | — |
| 21 Oct 2022 | Construction Fence | Permit Issued | Construction of new steel entrance doors and intercom and new concrete entrance ramp, stairs, and platform, with steel rails, and associated demolition of existing stairs, excavation, grading and backfill |
| 15 Sep 2022 | Construction Fence | Signed-off | CONSTRUCTION FENCE FOR PROTECTION OF PUBLIC. NO CHANGE IN USE, EGRESS, OR OCCUPANCY |
| 9 May 2022 | Construction Fence | Permit Issued | PATTERSON HOUSES, INSTALLATION OF +/- 680 LINEAR FEET OF 8 FEET HIGH CHAIN LINK FENCE. NO CHANGE IN USE, EGRESS OR OCCUPANCY |
| 18 Apr 2022 | Plumbing | Signed-off | Replacing hot water heaters and vacuum pumps with related piping |
| 5 Apr 2022 | Mechanical Systems | Signed-off | Related mechanical work for hot water heater replacement and vacuum pumps |
| 22 Mar 2022 | Mechanical Systems | Signed-off | Related mechanical work for hot water heater replacement and vacuum pumps |
| 22 Mar 2022 | Mechanical Systems | Signed-off | Related mechanical work for replacing hot water heaters and vacuum pumps with related piping |
| 21 Mar 2022 | Mechanical Systems | Signed-off | Related mechanical work for hot water heater replacement and vacuum pumps |
| 21 Mar 2022 | Structural | Signed-off | Related structural work for replacing hot water heaters and vacuum pumps with related piping |
| 21 Mar 2022 | Mechanical Systems | Signed-off | Related mechanical work for hot water heater replacement and vacuum pumps |
| 21 Mar 2022 | Structural | Signed-off | Related structural work for replacing hot water heaters and vacuum pumps with related piping |
| 21 Mar 2022 | Structural | Signed-off | Related structural work for replacing hot water heaters and vacuum pumps with related piping |
| 21 Mar 2022 | Structural | Signed-off | Related structural work for replacing hot water heaters and vacuum pumps with related piping |
| 16 Mar 2022 | Plumbing | Signed-off | Replacing hot water heaters and vacuum pumps with related piping |
| 16 Mar 2022 | Plumbing | Signed-off | Replacing hot water heaters and vacuum pumps with related piping |
| 16 Mar 2022 | Plumbing | Signed-off | Replacing hot water heaters and vacuum pumps with related piping |
| 15 Mar 2022 | Plumbing | Signed-off | Replacing hot water heaters and vacuum pumps with related piping |
| 15 Mar 2022 | Plumbing | Signed-off | Replacing hot water heaters and vacuum pumps with related piping |
| 15 Mar 2022 | Plumbing | Signed-off | Replace old with new 6 water closets, 7 lavatories, 1 urinal, 1 kitchen sink (2 bowls), 1 grease interceptor and 1 gas range |
| 15 Mar 2022 | Plumbing | Signed-off | Replacing hot water heaters and vacuum pumps with related piping |
| 15 Mar 2022 | Plumbing | Signed-off | Replacing hot water heaters and vacuum pumps with related piping |
| 4 Mar 2022 | Structural | Signed-off | Related structural work for replacing hot water heaters and vacuum pumps with related piping |
| 4 Mar 2022 | Structural | Signed-off | Related structural work for replacing hot water heaters and vacuum pumps with related piping |
| 4 Mar 2022 | Structural | Signed-off | Related structural work for replacing hot water heaters and vacuum pumps with related piping |
| 4 Mar 2022 | Structural | Signed-off | Related structural work for replacing hot water heaters and vacuum pumps with related piping |
| 4 Mar 2022 | Mechanical Systems | Signed-off | Related mechanical work for hot water heater replacement and vacuum pumps |
Showing the 50 most recent of 150. The full set is available in the interactive report.
Recorded documents
Deeds, mortgages and related instruments recorded against the lot. A recorded amount is not necessarily a market price.
| Recorded | Type | Amount | From | To |
|---|---|---|---|---|
| 6 May 2005 | DECL | — | — | — |
About this page
Compiled from New York City public records — data retrieved 6 days ago. Coverage on this parcel: 15 of 15 record groups populated. The derived figures — unused floor-area ratio, buildable area, the assessed-value trend and the per-unit ratios — are calculated by us and appear in no public dataset; the formulas are in the methodology.
This is a research tool, not advice. It is not a title search, a lien search, a survey or an inspection, and it does not replace any of them. If a figure here matters to a decision, verify it at the source. See Terms.